-
DELCO Intelligent Timer Electric Valve Actuator - IP67 PPO, Fast 7s Operation, Universal Voltage
Fast on/off: ≤7S response
-
DELCO QT Series Explosion-Proof Electric Actuator - Certified Safety & Wide Angle (0°-270°) Control
Materiall: Aluminum alloy
Protection Grade: CT4+ IP67 / IP68
Type: On-Off, Regulation, Intelligent
-
DELCO EX-DKV Small Explosion-Proof Electric Actuator Intelligent 6000 N.m Torque & 270° Rotation
Materiall: Aluminum alloy
Protection Grade: IP67
Type: On-Off, Regulation,Intelligent
-
DELCO DKV-IP67 Small Electric Actuator High Torque (4000 N.m) & Wide Angle Control
Materiall: Aluminum alloy
Protection Grade: IP67
Type: On-Off, Regulation, Intelligent
-
DELCO DKS-IP67 Electric Actuator High Torque Corrosion Resistant Industrial Control
Materiall: Aluminum alloy
Protection Grade: IP66 / IP67
Type: On-Off, Regulation, Intelligent
Certified IP67 Explosion-Proof Electric Valve Actuators
DELCO IP67 explosion-proof electric actuators are purpose-built to operate safely in volatile industrial atmospheres where flammable gases, vapors, or combustible dust clouds present an ignition risk. Certified to rigorous international flameproof standards—including ATEX and IECEx (Ex d IIC T4/T6 Gb and Ex tb IIIC T130°C Db)—our rugged enclosures are precision-machined to contain any internal explosion without allowing sparks, heat, or flame paths to ignite the surrounding ambient atmosphere. As a critical safety line within the DELCO electric actuator family, our flameproof units combine heavy-duty explosion containment with verified IP67 weatherproof ingress protection, providing trusted automation for oil refineries, chemical processing plants, offshore platforms, and LNG terminals.
Flameproof On/Off Isolation Duty (S2 Rating)
Engineered for emergency shutdown (ESD), tank farm tank-blanketing, and main pipeline isolation valves. Operates high-torque ball valves, plug valves, and butterfly valves with mechanical travel and torque switches certified spark-free under full motor stall conditions.
- Rated for Zone 1, Zone 2 (Gas) and Zone 21, Zone 22 (Dust)
- Double-reduction gear train with internal mechanical stops
- SIL 2 / SIL 3 capable for safety instrumented systems
Flameproof Modulating Control Duty (S4 Rating)
Engineered for continuous chemical throttling, gas compressor bypass, and refining blending lines. Features solid-state servo control electronics enclosed within flameproof housings, handling up to 1,200 starts per hour with analog 4–20 mA or digital fieldbus commands.
- High positioning precision within ±0.5% full scale
- Non-intrusive magnetic/infrared calibration (zero hot-work permit needed)
- Supports Modbus RTU, HART, and Profibus DP in hazardous zones
Why Safety Engineers Rely on DELCO Flameproof Actuators
Engineered with heavy-wall flameproof metallurgy, precision gap clearances, and non-intrusive calibration for uncompromising plant safety.
Certified ATEX & IECEx Flameproof
Certified to Ex d IIC T4/T6 Gb standards, covering the most volatile gas groups (including Hydrogen, Acetylene, and Ethylene). Capable of containing internal deflagrations without transmitting ignition energy to surrounding plant areas.
Precision-Machined Flame Paths
All mating cover flanges, cable penetrations, and drive shaft bushings feature ultra-precise cylindrical and spigot flame paths. These micro-clearance metal paths cool escaping combustion gases below ignition temperature before reaching the exterior.
Non-Intrusive Magnetic Setup
Technicians can calibrate travel limits, set torque thresholds, and view diagnostics through the explosion-proof tempered glass window using an external magnetic or infrared tool—eliminating hazardous hot-work permits on active refineries.
IP67 Weatherproof Protection
Beyond explosion-proof ratings, dual O-ring Viton seals provide certified IP67 ingress protection. Completely dust-tight and resistant to torrential rain, heavy offshore ocean spray, and temporary washdown immersion per IEC 60529.
Separate Ex d Terminal Compartment
Features an isolated flameproof wiring compartment separated from the primary motor and electronics chamber. Comes standard with explosion-proof threaded cable ports (NPT or Metric) designed for certified Ex d barrier glands.
Safe Declutchable Manual Override
Equipped with a spark-free bronze/stainless steel declutch mechanism and manual handwheel. The internal clutch disengages automatically when the electric motor is energized, ensuring complete operator safety during sudden remote actuations.
Flameproof Engineering Matrix & Valve Compatibility
Review standardized explosion-proof torque classes, hazardous area ratings, and typical valve pairings for petrochemical and oil & gas facilities.
| Flameproof Capacity Class | Rated Torque (Nm) | Hazardous Certification | Operating Stroke / Speed | Mounting Flange | Typical Hazardous Valve Sizing |
|---|---|---|---|---|---|
| Compact Flameproof Class | 50 – 150 Nm | Ex d IIC T4/T6 Gb / IP67 | 90° / 10 – 15 sec | ISO 5211 F05 / F07 | DN15 – DN50 (1/2" – 2") Ball & Plug Valves |
| Mid-Torque Flameproof Class | 200 – 600 Nm | Ex d IIC T4/T6 Gb / IP67 | 90° / 15 – 30 sec | ISO 5211 F07 / F10 | DN80 – DN150 (3" – 6") Ball & Butterfly |
| Heavy-Duty Flameproof Class | 800 – 2,000 Nm | Ex d IIC T4/T6 Gb / IP67 | 90° / 30 – 60 sec | ISO 5211 F10 / F12 / F14 | DN200 – DN350 (8" – 14") High-Pressure Ball |
| High-Capacity Flameproof Class | 2,500 – 4,000 Nm | Ex d IIC T4/T6 Gb / IP67 | 90° / 60 – 100 sec | ISO 5211 F14 / F16 | DN400 – DN600 (16" – 24") Pipeline Isolation |
| Multi-Turn Flameproof Class | 500 – 5,000+ Nm (Thrust to 300 kN) | Ex d IIC T4/T6 Gb / IP67 | Multi-Turn / 18 – 36 RPM | ISO 5210 F14 – F25 | Rising-Stem Gate & Globe Valves in Refineries |
Technical FAQs: Explosion-Proof Actuation
Critical engineering answers regarding hazardous gas classifications, hot-work permits, and flameproof installation compliance.
1. What is the difference between an Explosion-Proof (Ex d) and an Intrinsically Safe (Ex i) actuator?
Intrinsically Safe (Ex i) equipment operates on ultra-low electrical energy that is physically incapable of causing a spark. Because industrial electric valve actuators require substantial electrical power to drive high-torque motors, they cannot be intrinsically safe. Instead, they utilize Flameproof (Ex d) construction: heavy-walled metal enclosures designed to safely contain and cool any internal electrical explosion without permitting flame transmission to the surrounding atmosphere.
2. Why is non-intrusive calibration crucial in hazardous refinery environments?
In active oil, gas, and chemical plants, opening an electrical enclosure exposes live electronic components to surrounding volatile vapors, requiring an expensive, time-consuming plant shutdown and formal "Hot Work Permit." DELCO non-intrusive actuators feature external magnetic or infrared calibration, allowing technicians to commission travel limits, torque thresholds, and bus communications through the glass window safely while the plant remains live.
3. What hazardous gas groups and temperature classes are covered under Ex d IIC T4?
The IIC gas rating is the most demanding classification, covering highly volatile gases such as Hydrogen (H2) and Acetylene, in addition to Group IIB (Ethylene) and Group IIA (Propane/Methane). The T4 temperature rating guarantees that no exterior surface of the actuator will exceed 135°C under the most severe continuous duty cycles, ensuring surface temperatures stay safely below the ignition threshold of surrounding ambient gas mixtures.
4. What cable gland specifications are required to maintain the actuator's Ex d rating?
To uphold flameproof certification, field wiring must be installed using certified ATEX/IECEx Ex d barrier cable glands or conduit stopping boxes with approved setting compound. Using standard industrial glands compromises the flame path, creating a potential ignition hazard. DELCO actuators come standard with precision-machined NPT or Metric threaded conduit entries accompanied by certified Ex d metallic blanking plugs.
Factory Direct Supply for Hazardous Area Actuation
Safeguard your personnel and plant infrastructure with certified explosion-proof actuation. DELCO provides 100% factory explosion-proof gap verification, hydrostatic pressure testing, certified ATEX/IECEx documentation, and custom ISO 5211 valve mounting for global EPC contracts.