-
DELCO IP67-DK56-LBS Electric Stainless Steel Lug Butterfly Valve - SS304/316
Size Range: DN40-DN1200
Material:Cast Iron, WCB, SS304/316 etc.
Connection Standard: GB / ANSI / JIS /DIN
-
DELCO IP67-DK56-LB Electric Lug Type Butterfly Valve - Cast Iron, Rubber Lined
Size Range: DN40-DN1200
Material:Cast Iron, WCB, SS304/316 etc.
Connection Standard: GB / ANSI / JIS /DIN
-
DK56-LB-S Electric Stainless Steel Lug Butterfly Valve - Corrosion Resistant Dead-End Service
Size Range: DN40-DN1200
Material:Cast Iron, WCB, SS304/316 etc.
Connection Standard: GB / ANSI / JIS /DIN
-
DK56-LB Electric Cast Iron Lug Butterfly Valve - Dead-End Service & Automated Isolation
Size Range: DN40-DN1200
Material:Cast Iron, WCB, SS304/316 etc.
Connection Standard: GB / ANSI / JIS /DIN
-
Electric Actuated Lug-Type High-Performance Butterfly Valve (Double Offset)
Size Range: DN40-DN1200
Material:Cast Iron, WCB, SS304/316 etc.
Connection Standard: GB / ANSI / JIS /DIN
Electric Lugged Butterfly Valves (Full-Pressure Dead-End Isolation)
DELCO electric lugged butterfly valves are specialized quarter-turn flow control devices engineered with threaded bolt lugs protruding around the entire valve body perimeter. Unlike wafer valves that require continuous compression between two mating flanges, a lugged body connects independently to each pipeline flange using two separate sets of bolts. As an essential piping configuration within the DELCO electric butterfly valve collection, our lugged motorized valves allow piping contractors to completely disassemble downstream pipe runs, pumps, or strainers while holding full line pressure on the upstream side (true dead-end service), pairing heavy-duty ductile iron bodies with high-torque electric actuators.
True Dead-End Service Class
Engineered specifically for pump station headers, cooling tower discharge, and tank battery manifolds (DN50 to DN600 / 2" to 24"). Rated for full working pressure dead-end isolation (up to 16 bar / 230 psi) without requiring a downstream blind companion flange.
- Enables downstream pump removal without draining the entire pipeline header
- Tapped lugs machined strictly to UNC (ASME B16.5) or Metric (EN 1092-1) threads
- Bidirectional bubble-tight Class VI shut-off across full pressure differential
Heavy Mechanical Lug Rigidity
Eliminates the risk of through-stud bolt elongation common with wafer valves during thermal pipe cycling. Individual short cap screws anchor directly into threaded body lugs, preventing gasket crushing, flange misalignment, and thermal expansion leaks.
- Reinforced ductile iron (GGG50 / ASTM A536) lug ear construction
- Direct-mount ISO 5211 platform eliminates bracket backlash
- Resilient cartridge seat with molded phenolic or aluminum backing ring
Why Facility Engineers Specify DELCO Lugged Valves
Engineered with full threaded lug ears, independent bolting security, and cartridge-backed resilient liners for zero-maintenance pump isolation.
Single-Side Pipe Disassembly
Because each pipe flange bolts independently to threaded lugs, downstream equipment can be disconnected while upstream pressure remains fully locked and isolated, cutting plant maintenance downtime in half.
Hard-Backed Cartridge Seat
Features a resilient EPDM or NBR rubber liner bonded to a rigid phenolic or aluminum backing ring. Prevents seat distortion, stretching, or radial collapse under high flow velocity and dead-end full-pressure shut-off.
CNC Tapped Precision Lugs
All threaded lug ears are CNC drilled and tapped strictly to ASME B16.5 (UNC threads) or EN 1092-1 / DIN (Metric threads). Guarantees flawless thread engagement without on-site bolt binding or cross-threading.
Eliminates Thermal Bolt Stretch
Wafer valves use long all-thread rods that expand significantly under temperature changes, causing joint leaks. Lugged bodies use short hex bolts on each side, eliminating thermal expansion elongation and joint loosening.
Direct-Mount ISO 5211 Platform
Molded with an integral ISO 5211 top flange. Electric actuators bolt directly onto the valve neck without brackets or adapters, keeping stack height low and eliminating angular backlash during automated cycling.
Reliable Motorized Actuation
Paired with industrial electric actuators offering fast 10–25s quarter-turn operation, manual declutch handwheels, visual position indicators, IP67/IP68 enclosures, and optional 4–20mA proportional modulating cards.
Lugged Butterfly Valve Engineering Matrix & Specifications
Review standardized lug drilling configurations, dead-end pressure ratings, disc metallurgy, and typical municipal/HVAC applications.
| Lugged Design Class | Size Range | Lug Thread Standard | Dead-End Rating | Disc & Seat Trim | Typical Pump & Plant Services |
|---|---|---|---|---|---|
| Standard Water Lug Class | DN50 – DN600 (2" – 24") | ASME B16.5 150# (UNC) | 16 Bar (230 psi) Bidirectional | Ductile Iron (Epoxy) / EPDM | Potable Water, HVAC Chillers, Pump Isolation |
| Metric DIN Lug Class | DN50 – DN600 (2" – 24") | EN 1092-1 PN16 (Metric) | 16 Bar (PN16) Full Dead-End | 316SS Disc / EPDM or NBR | European Utility Headers, Wastewater Plants |
| Industrial Hydrocarbon Lug | DN50 – DN400 (2" – 16") | ASME 150# / PN16 | 16 Bar (230 psi) | CF8M (316SS) / NBR or FKM | Fuel Oil Lines, Lubrication Skids, Solvents |
| High-Performance Lug Class | DN80 – DN600 (3" – 24") | ASME Class 150 / 300 | 25 – 40 Bar (PN25/40) | Double-Eccentric / PTFE Seat | District Cooling, Medium-Pressure Steam |
| Corrosive Chemical Lug Class | DN50 – DN300 (2" – 12") | ASME 150# / DIN PN10 | 10 Bar (150 psi) | PTFE Lined Disc & Seat | Chemical Storage Tank Discharge Outlets |
Technical FAQs: Lugged Butterfly Valve Automation
Essential piping engineering guidance regarding dead-end service ratings, bolt specifications, and pump maintenance.
1. What is "dead-end service," and why can't wafer valves be used for it?
Dead-end service refers to installing a valve at the terminal end of a pipeline to isolate pressure while the downstream piping is removed. A wafer valve is clamped only by long through-studs compressed between two flanges; removing the downstream pipe requires removing the bolts, which releases the valve and dumps upstream fluid. A lugged valve bolts independently to the upstream flange, allowing the downstream pipe to be completely removed while holding full line pressure safely.
2. How are flange bolts specified for lugged butterfly valves?
Lugged valves use two separate sets of standard hex head cap screws (bolts) rather than all-thread studs. One set threads into the front lugs from the upstream flange, and the other threads into the rear lugs from the downstream flange. Bolt lengths must be calculated based on flange thickness plus thread engagement depth into the body lug to avoid bottoming out.
3. Why does DELCO use hard-backed cartridge seats instead of loose boot liners?
Loose rubber boot liners rely on pipe flange faces to pinch the rubber in place. In dead-end service when the downstream flange is removed, pressure on the upstream side can blow a loose rubber seat right out of the body. DELCO lugged valves feature a cartridge seat bonded to a rigid phenolic or aluminum backing ring that locks mechanically into the body, guaranteeing zero seat displacement under full dead-end pressure.
4. Can lugged butterfly valves be installed in vertical piping runs?
Yes. The threaded lugs provide rigid, self-centering support against the pipeline flanges, making them suitable for vertical risers as well as horizontal headers. For slurries or dirty fluids in horizontal lines, we recommend installing the valve with the stem horizontal to prevent sediment settling into the bottom stem journal.
Factory Direct Supply for Lugged Butterfly Valves
Simplify pump maintenance and dead-end isolation with factory-assembled lugged butterfly valves. DELCO provides 100% dead-end pressure testing, CNC precision lug tapping (UNC/Metric), direct-mount electric actuators, and fast volume dispatch for mechanical contractors.