Katup Solenoid Langsung Bekerja: True Zero-Differential Pressure & Millisecond Switching

Engineered for closed-loop fluid systems, atmospheric gravity draining, vacuum lines, and automated sampling skids where line pressure is negligible or fluctuating, the Delco direct-acting katup solenoid series provides immediate, positive fluid shutoff. Unlike pilot-operated designs that require line backpressure, the electromagnetic coil directly lifts the magnetic armature off the valve seat orifice. This delivers true zero-differential (ΔP = 0 bar) opening reliability, lightning-fast 10-to-20-millisecond cycle speeds, and zero susceptibility to clogged pilot holes across forged brass and stainless steel bodies.

2-Way Normally Closed (NC)
Spring keeps the plunger seated; coil energization directly opens the main orifice instantly from 0 bar up to 1.6 MPa.
2-Way Normally Open (TIDAK)
Continuous open flow path when de-energized; snaps shut upon power input for fail-safe safety venting and emergency bypass.
3-Way Universal Class
3-port 2-position architecture engineered for pneumatic actuator pilot control, fluid diversion, or stream blending.
Stainless Steel Precision Class
Forged 316L body with FKM or PTFE seats for analytical chromatography, pure gases, and aggressive fuels up to 50 bar.

Prestasi Teknis: Direct Plunger Actuation Engineering

True Zero Differential (ΔP = 0 Bar)

Direct magnetic connection opens the seal without needing upstream line pressure. Functions reliably in rough vacuum systems, low-pressure gas, and gravity-fed tanks.

Sub-20ms Ultra-Fast Cycling

Low-mass stainless armatures execute full travel in 10 to 20 milliseconds, delivering superior volumetric dosing repeatability in high-speed bottling and analytical machinery.

Zero Pilot Orifice Clogging

Free of microscopic pilot bypass bleed holes, direct-acting valves tolerate light particulate loads and slightly viscous fluids without the pilot-hole sticking common in pilot valves.

High Vacuum to 1.6 MPa Containment

Precision CNC-ground valve seats and resilient elastomer seals ensure zero-bubble shutoff from negative vacuum pressures down to 1.3 × 10-2 Pa up to 16 bar.

Kumparan Duty Kontinu 100% ED

Epoxy-encapsulated Class H (180°C) or Class F (155°C) copper coils endure non-stop, 24/7 energization in enclosed control cabinets without thermal drop-out or coil burnout.

Multi-Port 2/2 and 3/2 Flexibility

Available in 2-way on/off as well as 3-way universal configurations (Biasanya Tertutup, Terbuka Normal, or Diverting) to suit complex OEM instrument manifolds.

Matriks Spesifikasi Teknis

Parameter 2-Way NC Forged Brass 2-Way NC 316 Stainless 3-Way Universal Class High-Pressure Micro-Orifice
Rentang Ukuran Nominal DN1.5 – DN10 (1/8" – 3/8") DN1.5 – DN15 (1/8" – 1/2") DN1.0 – DN6.0 (1/8" – 1/4") DN0.8 – DN3.0 (1/8" – 1/4")
Tekanan Operasi 0 – 1.6 MPa (Zero ΔP Required) 0 – 1.6 MPa (0 – 16 Bar) 0 – 1.0 MPa (0 – 10 Bar) 0 – 5.0 MPa (Up to 50 Bar)
Material Bodi Forged Brass CW617N / HPb59-1 ASTM A351 CF8M / 316 SS Forged Brass / 316 SS Forged AISI 316L Stainless Steel
Material Segel NBR (Standar), FKM, EPDM FKM (Viton), PTFE, EPDM NBR, FKM, PTFE MENGINTIP, PCTFE, Synthetic Ruby
Rentang Suhu Operasi -10°C to +90°C (NBR) / 130°C (FKM) -20°C hingga 150°C (FKM/PTFE) -10°C hingga 120°C -30°C hingga 150°C
Waktu Respons Switching 12 – 25 ms 15 – 25 ms 10 – 20 ms 8 – 15 ms
Koneksi Akhir Female G Thread (ISO 228-1), NPT perempuan (ASME B1.20.1), Sub-base / Manifold Mount
Coil Specifications 12VDC, 24VDC, 24VAC, 110VAC, 220VAC (50/60 Hz); IP65 DIN 43650 Form A/B/C; Kelas F (155°C) / Class H (180°C); 100% ED
* 100% diperiksa pabrik: Uji tekanan hidrostatik 1,5x, uji kebocoran dudukan rapat gelembung (EN 12266-1 Tarif A), dan tes kerusakan dielektrik isolasi kumparan pada 1,500V.

Pertanyaan yang Sering Diajukan: Katup Solenoid Langsung Bekerja

Q1: Why is a Direct-Acting Solenoid Valve mandatory for gravity feed and vacuum lines?

Pilot-operated valves rely on upstream line pressure to push open the main diaphragm or piston. If line pressure is zero or negative (such as an atmospheric gravity draining tank or vacuum degassing chamber), there is insufficient hydraulic energy to lift the seal, causing the valve to remain stuck closed. Direct-acting valves use purely magnetic pull to lift the seal, operating independently of line pressure.

Q2: What is the relationship between orifice size and operating pressure in direct-acting valves?

In direct-acting valves, the magnetic coil must overcome the product of line pressure and orifice area (Force = Pressure × Area). Oleh karena itu, maximum operating pressure is inversely proportional to orifice diameter. For small orifices (1.0–2.5 mm), the valve can easily hold 1.6 to 5.0 MPa. For larger orifices (6.0–10.0 mm), operating pressure is typically limited to 0.4–0.7 MPa unless a high-power boost coil is fitted.

Q3: What is the functional difference between 2-way and 3-way direct acting solenoid valves?

A 2-way valve has one inlet and one outlet, functioning as a straightforward on/off shutoff control. A 3-way valve features three pipe ports and two internal seats. Depending on port connection, it can serve as Normally Closed (exhausting an actuator cylinder when de-energized), Terbuka Normal, mengalihkan perhatian (routing one inlet to two alternate outlets), or Mixing (blending two inlets into one common outlet).

Q4: How does Delco prevent coil overheating during 100% continuous duty cycles?

Continuous energization can elevate coil temperature and cause insulation breakdown. Delco employs Class H (180°C) and Class F (155°C) enameled copper wire encapsulated in thermosetting epoxy. This provides rapid heat dissipation to the ambient air and prevents moisture absorption, ensuring that steady-state operating temperatures remain well below thermal breakdown limits.

Pasokan Pabrik Langsung: Precision Direct-Acting Solenoid Valves

High-volume inventory of forged brass and 316 stainless steel direct-acting solenoid valves. Uji tekanan pabrik 100%, EN 12266-1 Rate A zero-bubble certified, and ready for rapid OEM equipment integration.